Net Optics Switch N IDP POBPSX 001 N IDP POBPLX 002 User Manual

Installation Guide for  
Optical Bypass Switch  
Models N-IDP-POBPSX-001, N-IDP-POBPLX-002  
Doc. IGNET-N-IDP-POBPSX-001/LX-002 Revised 09/05  
 
Optical Bypass Switch  
PLEASE READ THESE LEGAL NOTICES CAREFULLY.  
By.using.a.Net.Optics.Optical.Bypass.Switch.you.agree.to.the.terms.and.conditions.of.usage.set.forth.  
by.Net.Optics,.Inc .  
.
No.licenses,.express.or.implied,.are.granted.with.respect.to.any.of.the.technology.described.in.this.  
manual .Net.Optics.retains.all.intellectual.property.rights.associated.with.the.technology.described.in.  
this.manual .This.manual.is.intended.to.assist.with.installing.Net.Optics.products.into.your.network  
Trademarks and Copyrights  
©.2005.by.Net.Optics,.Inc ..Net.Optics®.is.a.registered.trademark.of.Net.Optics,.Inc .Additional.  
company.and.product.names.may.be.trademarks.or.registered.trademarks.of.the.individual.companies.  
and.are.respectfully.acknowledged  
Additional Information  
Net Optics, Inc. reserves the right to make changes in specifications and other information contained  
in.this.document.without.prior.notice .Every.effort.has.been.made.to.ensure.that.the.information.in.  
this.document.is.accurate .Net.Optics.is.not.responsible.for.typographical.errors  
 
Optical Bypass Switch  
Introduction  
Net.Optics.Optical.Bypass.Switches.provide.a.permanent.and.trouble-free.  
access.port.for.in-line.network.security.and.monitoring.devices .The.Opti-  
cal Bypass Switch automatically switches network traffic through added IDP  
devices.or.bypasses.devices.that.are.about.to.be.removed .Prevent.link.failure.  
when.attached.IDP.devices.lose.power.by.powering.the.Bypass.Switch.and.  
in-line.device.from.the.same.power.source .  
Uninterrupted traffic  
The Optical Bypass Switch supports fail-open monitoring with any fiber IDP  
device.when.it.shares.the.same.power.source.as.the.IDP .While.the.Optical.  
Bypass Switch is receiving power, it diverts network traffic to attached IDP. In  
this state, all in-line traffic is routed directly to the IDP connected to the Opti-  
cal.Bypass.Switch .  
When the Optical Bypass Switch loses power, in-line traffic continues to flow  
through.the.network.link,.but.is.no.longer.routed.through.the.device .This.al-  
lows.the.network.devices.to.be.removed.and.replaced.without.network.down-  
time. Once power is restored to the Optical Bypass Switch, network traffic is  
seamlessly.diverted.to.the.IDP,.allowing.it.to.resume.its.critical.functions  
Simply Plug It In  
Each.Bypass.Switch.includes.all.the.cables.and.power.supplies.you.need.to.  
quickly.connect.to.an.IDP .Three.quick.steps.is.all.it.takes.to..establish.a.secure.  
connection.point.for.inline.devices  
Key Features  
Passive, Secure Technology  
• Fail-open monitoring with any GigaBit fiber in-line appliance at speeds of  
1000.Mbps  
•. Increased.reliability.on.critical.network.links  
•. High-speed.optical.switching.with.minimal.insertion.loss  
1
 
Optical Bypass Switch  
Key Features (continued)  
Ease of Use  
•. LED.indicator.shows.power.status  
•. Front-mounted.connectors.support.easy.installation.and.operation  
•. Cables.included.for.plug-and-play.deployment  
•. Silk-screened.application.diagram.illustrates.all.connections.for.easy..  
deployment  
•. Optional.19-inch.rack.frames.holds.two.Bypass.Switches  
•. Tested.and.compatible.with.all.major.manufacturers’.monitoring.devices,.  
including.protocol.analyzers,.probes,.and.intrusion.detection/prevention.  
systems  
Support  
•. Net.Optics.offers.free.technical.support.throughout.the.lifetime.of.your.  
purchase. Our technical support team is available from 8 am to 5 pm Pacific  
Time,.Monday.through.Friday.at.+1.(408).737-7777.and.via.email.at.ts-  
support@netoptics com .FAQs.are.also.available.on.Net.Optics.website.at.  
www netoptics com  
2
 
Optical Bypass Switch  
Product Diagram  
Optical Bypass Switch  
®
A
A
B
OUT  
IN  
OUT  
IN  
Monitor  
Network  
GigaBit  
Figure.1 .Front.View.Panel  
Silk Screen Diagram  
Power Connector  
®
®
Tx  
Rx  
A
Tx  
Rx  
B
Tx  
Rx  
A
Network A  
Tx  
Rx  
B
Network B  
Monitor A  
Monitor B  
Figure.2  
 
Optical Bypass Switch  
Power Loss Bypass  
The.Optical.Bypass.Switch.protects.link.integrity.when.the.in-line.appliance.  
loses.power .When.the.Bypass.Switch.is.receiving.power.it.is.in.Bypass.  
Disabled.(OFF.).mode .In.Bypass.Disabled.mode.the.switch.sends.network.  
traffic through the connnected device.  
Bypass Disabled Mode  
When the Bypass Switch is in Bypass Disabled  
mode, all in-line traffic is routed through the  
Juniper IDP appliance.  
1
Bypass Switch  
Internet  
®
A
B
A
B
Router  
Firewall  
Switch  
Switch  
2
The Bypass switch is  
receiving power from  
the DC power supply.  
Juniper Networks  
IDP-1100  
Figure.3  
When.power.to.the.Bypass.switch.fails,.it.enters.Bypass.Enabled.(ON).mode.  
and network traffic bypasses the connected device until power to the switch is  
restored  
Bypass Enabled Mode  
When the Bypass Switch is in Bypass Enabled  
1
mode, all in-line traffic continues to flow on the  
network link without being directed through the  
Juniper IDP appliance  
Bypass Switch  
Internet  
®
A
B
A
B
Router  
Firewall  
Switch  
Switch  
Because in-line traffic is no longer  
flowing through the IDP, the appliance  
may be removed and replaced without  
downtime.  
3
2
When there is no power to  
the Bypass switch, it enters  
Bypass Enabled mode.  
Juniper Networks  
IDP-1100  
Figure.4  
 
Optical Bypass Switch  
Unpacking and Inspection  
Unpack.the.Optical.Bypass.Switch,.power.supply,.and.cables.provided .Each.  
Optical.Bypass.Switch.is.delivered.with.the.following:  
For models N-IDP-POBPSX-001, N-IDP-POBPLX-002:  
•..1.DC.power.supply  
• 2 Duplex SC-SC fiber cables  
• 2 Duplex SC-LC fiber cables  
•..1.Manual  
If.any.component.is.missing.or.damaged,.contact.Net.Optics.Customer.  
Service.immediately  
Connecting the Optical Bypass Switch to the  
Network  
1 .Connect.Network.Port.A.to.the.appropriate.switch,.server.or.router.device.  
using a duplex SC fiber cable. This acts as your DCE interface.  
2 .Connect.Network.Port.B.to.the.appropriate.switch,.server.or.router.device.  
using a duplex SC fiber cable. This acts as your DTE interface.  
3 .Verify.that.the.Bypass.Switch.Network.Ports.are.cabled.in-line.between.two.  
devices  
5
 
Optical Bypass Switch  
Connecting the Optical Bypass Switch to the In-line  
Security Device  
1 .Connect.Monitoring.Port.A.to.the.in-line.appliance.Port.A.using.a.duplex.  
SC-to-LC fiber cable. This will act as your DCE Interface.  
2 .Connect.Monitoring.Port.B.to.the.in-line.appliance.Port.B.using.a.duplex.  
SC-to-LC fiber cable. This will act as your DTE interface.  
3 .Verify.that.the.Switch.Monitoring.Ports.are.cabled.in-line.between.two.  
devices  
4 .Connect.the.power.supply.to.the.switch .Make.sure.you.connect.the.  
switches’.power.supply.to.the.same.power.sources.that.in-line.appliance.is.  
using  
Connect Fiber In-Line Ports  
1
DTE  
Tx  
Rx  
Rx  
Tx  
Rack-Mount Frame  
Holds 2 Switches  
DCE  
Tx  
Rx  
Rx  
Tx  
Connect SC Fiber  
Cables  
2
®
A
B
A
A
BB  
Switch  
Network  
Monitor  
®
A
B
A
A
BB  
B
STEM  
Network  
Monitor  
To  
F
7x  
switch, server,  
or router  
(DCE)  
10Ba  
seT  
1x  
2x  
3x  
4x  
5x  
6
Æ
MS  
CIS  
COY  
berDA  
seTX/  
8
B
F
7x  
DIFi  
A
10Ba  
To  
switch, server, or router  
(DTE)  
1x  
2x  
3x  
4x  
5x  
6
C
O
N
S
O
L
U
T
P
E
T
H
I
C
K
N
E
T
A
T
M
A
S
W
1
T
M
D
C
E
D
T
E
R
E
M
O
T
T
H
I
N
N
E
T
E
IPS  
Figure.5  
 
Optical Bypass Switch  
Specifications  
Splitter Specifications:  
Fiber Type: Multimode:.Corning.62 5/125µm,.wavelength,.850nm  
Insertion Loss: Network Port: ≤ 1.25 dB  
Monitor Port: ≤ 1.25 dB  
Fiber Type: Singlemode:.Corning.8 5/125µm,.wavelength,.1300nm  
Insertion Loss: Network Port: ≤ 1.25 dB  
Monitor Port: ≤ 1.25 dB  
Note: There is no insertion loss when the switch is not receiving power  
and is in Bypass Disabled mode.  
Operating Specifications:  
Operating Temperature: 5˚C to 40˚C  
Storage Temperature: -10˚C to 70˚C  
Relative.Humidity:.10%.min,.95%.max,.non-condensing  
Mechanical Specifications:  
Power.Supply:.Input.Power:.100-250V,.0 5A,.47-63Hz  
. .Output.Power:.5V,.2 4A  
Dimensions:.1 125”.high.x.6 0”.deep.x.6 5”.wide  
Connectors:  
(2).Duplex.SC.connectors.(monitoring.ports)  
(2).Duplex.SC.connectors.(network.ports)  
 
Optical Bypass Switch  
Limitations on Warranty and Liability  
Net.Optics.offers.a.limited.warranty.for.all.its.products .IN.NO.EVENT.SHALL.NET.OPTICS,.INC .  
BE.LIABLE.FOR.ANY.DAMAGES.INCURRED.BY.THE.USE.OF.THE.PRODUCTS.(INCLUD-  
ING.BOTH.HARDWARE.AND.SOFTWARE).DESCRIBED.IN.THIS.MANUAL,.OR.BY.ANY.  
DEFECT.OR.INACCURACY.IN.THIS.MANUAL.ITSELF .THIS.INCLUDES.BUT.IS.NOT.LIM-  
ITED.TO.LOST.PROFITS,.LOST.SAVINGS,.AND.ANY.INCIDENTAL.OR.CONSEQUENTIAL.  
DAMAGES.ARISING.FROM.THE.USE.OR.INABILITY.TO.USE.THIS.PRODUCT,.even.if.Net.  
Optics.has.been.advised.of.the.possibility.of.such.damages .Some.states.do.not.allow.the.exclusion.  
or.limitation.of.implied.warranties.or.liability.for.incidental.or.consequential.damages,.so.the.above.  
limitation.or.exclusion.may.not.apply.to.you  
Net.Optics,.Inc .warrants.this.Optical.Bypass.Switch.to.be.in.good.working.order.for.a.period.of.ONE.  
YEAR.from.the.date.of.purchase.from.Net.Optics.or.an.authorized.Net.Optics.reseller  
Should.the.unit.fail.anytime.during.the.said.ONE.YEAR.period,.Net.Optics.will,.at.its.discretion,.  
repair.or.replace.the.product .This.warranty.is.limited.to.defects.in.workmanship.and.materials.and.  
does not cover damage from accident, disaster, misuse, abuse or unauthorized modifications.  
If.you.have.a.problem.and.require.service,.please.call.the.number.listed.at.the.end.of.this.section.and.  
speak.with.our.technical.service.personnel .They.may.provide.you.with.an.RMA.number,.which.must.  
accompany.any.returned.product .Return.the.product.in.its.original.shipping.container.(or.equivalent).  
insured.and.with.proof.of.purchase  
Additional Information  
Net Optics, Inc. reserves the right to make changes in specifications and other information contained  
in.this.document.without.prior.notice .Every.effort.has.been.made.to.ensure.that.the.information.in.  
this.document.is.accurate .Net.Optics.is.not.responsible.for.typographical.errors  
THE.WARRANTY.AND.REMEDIES.SET.FORTH.ABOVE.ARE.EXCLUSIVE.AND.IN.LIEU.OF.  
ALL.OTHERS,.EXPRESS.OR.IMPLIED .No.Net.Optics.reseller,.agent,.or.employee.is.authorized.  
to make any modification, extension, or addition to this warranty.  
Net.Optics.is.always.open.to.any.comments.or.suggestions.you.may.have.about.its.products.and/or.  
this.manual  
Send.correspondence.to.  
Net.Optics,.Inc .  
1130.Mountain.View.Alviso.Road.  
Sunnyvale,.CA.94089-2237.USA.  
Telephone:.+1.(408).737-7777.  
Fax:.+1.(408).745-7719.  
Email:.info@netoptics com/Internet:.www netoptics com  
All.Rights.Reserved .Printed.in.the.U S A .No.part.of.this.publication.may.be.reproduced,.transmit-  
ted,.transcribed,.stored.in.a.retrieval.system,.or.translated.into.any.language.or.computer.language,.  
in.any.form,.by.any.means,.without.prior.written.consent.of.Net.Optics,.Inc ,.with.the.following.  
exceptions:.Any.person.is.authorized.to.store.documentation.on.a.single.computer.for.personal.use.  
only.and.that.the.documentation.contains.Net.Optics’.copyright.notice  
 
©.2005.by.Net.Optics,.Inc .All.Rights.Reserved ..  
 

Miele Ventilation Hood DA409 User Manual
Milwaukee Camera Accessories 2311 21 User Manual
Milwaukee Drill 0204 1070 User Manual
Napoleon Fireplaces Indoor Fireplace BGNV40 P User Manual
NordicTrack Home Gym NTS58740 User Manual
One for All Universal Remote URC 6512 User Manual
Orion Car Audio Car Stereo System 2150XTR User Manual
P3 International Portable Radio E 9300 User Manual
Paradyne Network Hardware 8747 User Manual
Patton electronic Network Router 4630 Series User Manual