OPERATING INSTRUCTIONS
MIXER POWER AMPLIFIER
BG-1015
BG-1030
BG-1060
BG-1120
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
• Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
• When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
• Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
• When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
When the Unit is in Use
• Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest TOA dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
• Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
· If you detect smoke or a strange smell coming
from the unit.
· If water or any metallic object gets into the unit
· If the unit falls, or the unit case breaks
· If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
• Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
· If it is malfunctioning (no tone sounds.)
• Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
• To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest TOA dealer.
• Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
• Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
• Contact your TOA dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
• Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
• If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
CAUTION
• Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
When Installing the Unit
• Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
ATTENTION
L'appareil ne doit pas être exposé aux éclaboussures ou écoulements et tous objets remplis de liquide, tels
que vases, ne doivent pas être sur l’appareil.
3
TABLE OF CONTENTS
1. GENERAL DESCRIPTION ............................................................................. 5
2. FEATURES .......................................................................................................... 5
3. NOMENCLATURE AND FUNCTIONS
Front ......................................................................................................................... 6
Rear .......................................................................................................................... 7
4. INPUT CONNECTIONS ................................................................................... 8
5. OUTPUT CONNECTIONS .............................................................................. 9
6. PLUG-IN MODULE INPUT PORT
6.1. Module Installation ............................................................................................ 9
6.2. Module Selector Switch Settings ...................................................................... 10
7. EQUIPMENT SETTINGS
7.1. Mute Function
7.1.1. Mute operation A .................................................................................... 10
7.1.2. Mute operation B .................................................................................... 11
7.2. TEL Input Impedance Selection ....................................................................... 11
7.3. AUX, PROGRAM, MODULE (BGM) Output Selection ..................................... 12
7.4. Phantom Power On/Off Setting for Microphone Input ...................................... 12
7.5. Changing MIC and PROGRAM Input Types
7.5.1. MIC input ................................................................................................ 12
7.5.2. Program input ........................................................................................ 13
8. INSTALLATION ................................................................................................. 13
9. RACK MOUNTING ........................................................................................... 13
10. CONTROL SETTINGS .................................................................................... 14
11. DIMENSIONAL DIAGRAM ............................................................................ 14
12. BLOCK DIAGRAM ........................................................................................... 15
13. SPECIFICATIONS ............................................................................................ 16
Accessories ............................................................................................................. 16
Optional products .................................................................................................... 16
4
1. GENERAL DESCRIPTION
TOA's BG-1015, BG-1030, BG-1060, and BG-1120 Mixer Power Amplifiers can mix up to a total of 5
independent input signals. Power output is rated at 15 W for the BG-1015, 30 W for the BG-1030, 60 W for the
BG-1060, and 120 W for the BG-1120. All units are ideal for use in sound systems requiring small power
outputs.
2. FEATURES
• 3 balanced inputs, 1 unbalanced input, and 1 module input
• Phantom-powered microphone input
• Telephone paging input
• Compatible with all 900 Series modules (except for mute buss functions)
• Wide frequency response ranging from 50 Hz to 20 kHz
• Low distortion and low noise level
• Excellent output regulation
• Three different speaker outputs: 4 Ω, 25 V, and 70 V
• MOH (Music On-Hold) output: 1 V, 600 Ω
• 1W output terminal: 8 Ω
• Independent bass and treble controls
• Input and output terminals for connection of signal processors
• Two different mute functions
• Overcurrent and thermal protection circuitries
• Compact and lightweight
• Desktop or 19" rack mountable
5
3. NOMENCLATURE AND FUNCTIONS
[Front]
5
6
7
8
9
3
4
MIC
TEL
PROGRAM
AUX
MODULE
SIGNAL
PEAK
POWER
2
1
0
10
0
10
0
10
0
10
0
10
ON
OFF
INTEGRATED AMPLIFIER BG-1120
This figure represents the BG-1120.
1. Power switch
5. Microphone input volume control
Press to turn ON the power. Press again to turn
the power OFF.
Adjusts the microphone input volume. Turn
clockwise to increase and counterclockwise to
decrease.
Note
Amplifier operation is enabled about 3 seconds
after the power switch is pressed.
6. Telephone paging input volume control
Adjusts the telephone paging input volume. Turn
clockwise to increase and counterclockwise to
decrease.
2. Power indicator
Lights green when the power is switched on.
7. Program input volume control
3. Signal level indicator
Adjusts the Program input volume. Turn clockwise
to increase and counterclockwise to decrease.
Lights green when the speaker output signal level
exceeds 20 dB.
8. AUX input volume control
4. Peak indicator
Adjusts the AUX input volume. Turn clockwise to
increase and counterclockwise to decrease.
Lights when the output signal level exceeds the
point at which the signal begins to distort. If this
indicator remains lit, reduce the volume at each
volume control so that the indicator only lights
momentarily.
9. Module input volume control
Adjusts the Module input volume. Turn clockwise
to increase and counterclockwise to decrease.
Protection function to be noted on operation
When the temperature of unit's internal heat sink exceeds the specified limit, the protection circuit is
activated and the output is disconnected from the circuit. Output is automatically restored when the heat
sink cools down below the temperature limit.
6
[Rear]
13
14
15 17 19
18
22 23
24
Blank panel
120V
MAX 500W
60Hz
SENSE
UNIT
BREAKER
OUTLET
BREAKER
MUTE
MODULE
PUSH
RESET
PUSH
RESET
4
A
4
A
0
10
A
B
PAGE
BGM
PROGRAM
TEL
MIC
BASS
0
TREBLE
0
12
11
G
COM HOT
G
COM HOT
G
COM HOT NC
AUX
UNSWITCHED
–
+
–
+
27
OUTPUT 120
W
OUTPUT
1
W
MOH
MUTE
120V
60Hz
PREAMP
OUT
POWER
IN
150W
COM 4Ω 25V 70V
8Ω COM 600Ω COM
G
OUTPUT
1
W
MOH
0
10
0
10
CLASS
2
WIRING
10
28
20 21
25 26
This figure represents the BG-1120.
16
10. Power cord
15. Input terminal block
Connect this cord to an AC outlet of 120 V AC.
Used for connection of MIC, TEL and
PROGRAM inputs. (Refer to p. 8.)
11. Ground terminal
A functional ground terminal.
16. Output terminal block
Used for connection of speaker outputs, 1 W
output, MOH (Music On-Hold) output, and Mute
control signals. (Refer to p. 9 and p. 10.)
12. AC outlet [UNSWITCHED]
Continuously supplies up to 500 W of AC power
to connected external equipment.
17.Sensitivity control
13. Breaker [UNIT]
Adjusts the sensitivity of the mute circuit. Rotate
clockwise to increase sensitivity, and
counterclockwise to reduce sensitivity.
Cuts off the AC power to the unit when its input
current exceeds the allowable value.
Note
18. Bass control
The yellow button in the breaker pops out to
indicate that the breaker has tripped. After
turning off the power and eliminating the cause
of the breaker trip, press the button to reset the
breaker.
Adjusts the bass frequency band level of speaker
outputs for MODULE (BGM), PROGRAM, and
AUX input signals. Rotate clockwise to increase
bass output, and counterclockwise to reduce it.
The center position provides flat characteristics.
14. Breaker [OUTLET]
19. Treble control
Cuts off the AC power supply from the AC outlet
Adjusts the treble frequency band level of
speaker outputs for MODULE (BGM),
PROGRAM, and AUX input signals. Rotate
clockwise to increase treble output, and
counterclockwise to reduce it. The center
position provides flat characteristics.
if current output exceeds 4 A.
Note
The yellow button in the breaker pops out to
indicate that the breaker has tripped. After
turning off the power and eliminating the cause
of the breaker trip, press the button to reset the
breaker.
7
20. 1 W output volume control
25.Preamplifier output terminal [PREAMP OUT]
Used for connection of output signals to external
signal processing equipment such as limiters and
equalizers.
Adjusts the 1 W OUTPUT level. Rotate clockwise
to increase and counterclockwise to decrease.
21. MOH output volume control
Adjusts the MOH (Music On-Hold) output signal
level. Rotate clockwise to increase and
counterclockwise to decrease.
26. Power amplifier input terminal [POWER IN]
Used for connection of input signals from
external signal processing equipment such as
limiters and equalizers.
22. Mute selector switch
Changes the type of mute operation.
(Refer to p. 10.)
27.Module input port
Optional 900 Series modules can be installed
here.
23. Module selector switch
Note
Selects the output terminal for the module signal.
Set the switch to the PAGE position when using
the paging module, and to the BGM position
when using the BGM module.
For details concerning 900 Series modules,
contact your nearest TOA dealer.
28. Terminal cover
Make sure that the terminal cover is reattached
after speaker output terminal connection
completion.
24. AUX input terminals (2P RCA pin jack)
An internal mixing type of jack.
Used for connection of external equipment input
signals. (Refer to p. 8.)
4. INPUT CONNECTIONS
[MIC input connections]
G
COM HOT
MIC
H
C
E
[TEL and PROGRAM input connections]
G
COM HOT
H
Input source
C
E
[AUX input connections]
AUX
H
E
H
E
Input source
Input source
8
5. OUTPUT CONNECTIONS
[Output terminals]
Each amplifier has 3 speaker outputs: 4 Ω, 25 V and 70 V. Use only one of these outputs for connection.
Class 2 wiring may be used.
Note: The impedance in the figure below represents the total impedance of the speaker system.
COM 4Ω 25V 70V
COM 4Ω 25V 70V
COM 4Ω 25V 70V
5.2 Ω (BG-1120)
10.4 Ω (BG-1060)
21 Ω (BG-1030)
42 Ω (BG-1015)
40.8 Ω (BG-1120)
81.7 Ω (BG-1060)
163 Ω (BG-1030)
330 Ω (BG-1015)
4 Ω
25 V line
70 V line
[MOH output connections]
[OUTPUT 1 W output connections]
The MOH output is rated at 1 V/600 Ω
The OUTPUT 1 W output is rated at 1 W/8 Ω
8Ω COM
600Ω COM
G
E
C
H
8Ω
6. PLUG-IN MODULE INPUT PORT
A single port for TOA plug-in modules is located on the unit's rear panel. Any 900 Series plug-in module can
be inserted into this port.
Note: Consult your nearest TOA dealer for selection of appropriate module types.
Be sure to turn off the power before performing the following operations:
6.1. Module Installation
Mixer power amplifier
Step 1. Remove the blank panel covering the module
slot on the rear panel.
Step 2. Align the module board with the top and
bottom guide rails, and press in.
Step 3. Using the screws supplied with the module,
secure the module to the rear panel.
Guide rail
900 Series plug-in module
Module mounting screw (supplied with the module)
9
6.2. Module Selector Switch Settings
Set the rear panel-mounted Module Selector Switch to either the PAGE or BGM position, depending on the
output terminal to which the module signal is to be sent.
MODULE
PAGE: Signals from the installed module are only sent to the
speaker outputs.
PAGE
BGM
BGM: The terminal to which the signal from the module is to
be output differs depending on jumper wire settings
inside the unit. (Refer to p. 12.)
Module selector switch
Set both the bass and treble controls to the center position when using the equalizer module.
Caution: Make sure that the supplied blank panel is placed over the connector port when the port is not in
use.
7. EQUIPMENT SETTINGS
Caution: Be sure to leave settings to a qualified technician.
7.1. Mute Function
MUTE
The unit features 2 different mute functions, A and B. Mute A or
B can be selected with the rear panel-mounted Mute Selector
Switch.
A
B
Mute selector switch
7.1.1. Mute operation A
The mute function can be activated either by the TEL, MIC, or MODULE (PAGE) input signal, or by shorting
the rear panel-mounted mute terminals.
[Mute signal settings]
Input signals to activate the mute function can be selected by the internal jumper wire settings. The TEL, MIC,
and MODULE (PAGE) input signals are all factory-preset (Jumpers JP207, JP208, and JP209 are set) as
muting signals.
Cut off the jumper wire corresponding to the input signal to be disabled for muting.
In any case, shorting the rear-mounted Mute terminals can also actuate the mute function.
JP208
JP207
JP209
T203
T202
T201
Preamplifier board
Note
If Module Input is selected, the mute function can only be used when the Module Selector Switch is set to the
PAGE position.
10
[Muted signal settings]
Use the unit's internal jumper switch JP301 to select the signal to be muted. Select either the input signal from
the TEL, MIC, and MODULE (PAGE) terminals or from the AUX, PROGRAM, and MODULE (BGM) terminals
as the signal to be muted.
Jumper switch JP301
PAGE: TEL, MIC, MODULE ( PAGE)
BGM: AUX, PROGRAM, MODULE ( BGM)
Note: Selection is factory-preset to the input from AUX, PROGRAM,
Preamplifier output board
and MODULE (BGM) terminals.
7.1.2. Mute operation B
The mute function can be controlled by way of the rear panel-mounted Mute terminal.
Note: The mute function cannot be controlled by means of an input signal.
[Mute terminal]
: Channel is ON.
: Signal is muted.
Close
Open
MIC
MIC
TEL
TEL
MODULE (PAGE)
AUX
MODULE (PAGE)
AUX
PROGRAM
MODULE (BGM)
PROGRAM
MODULE (BGM)
7.2. TEL Input Impedance Selection
The impedance is factory-preset to 10 kΩ. To switch to 600 Ω, change the position of the unit's internal jumper
switch JP204.
600 Ω 10 kΩ
T203
T202
T201
Jumper switch JP204
Preamplifier board
11
7.3. AUX, PROGRAM, MODULE (BGM) Output Selection
Operations shown in the following table can be enabled with the unit's internal jumper settings.
[OUTPUT 15 W/30 W/60 W/120 W]
[OUTPUT 1 W, MOH]
Jumpered
Cut
Jumpered
Cut
Jumpered
Cut
AUX:
AUX:
ON
OFF
ON
Jumpered
AUX:
AUX:
ON
OFF
ON
JP210
JP211
JP212
JP213
Cut
PROGRAM:
PROGRAM:
MODULE (BGM): ON
MODULE (BGM): OFF
Jumpered
PROGRAM:
PROGRAM:
MODULE (BGM): ON
MODULE (BGM): OFF
JP214
Cut
OFF
OFF
Jumpered
JP215
Cut
[OUTPUT 1 W, MOH]
[OUTPUT 15 W/30 W/60 W/120 W]
JP213: AUX
JP214: PROGRAM
JP215: MODULE (BGM)
JP212: MODULE (BGM)
JP211: PROGRAM
JP210: AUX
Preamplifier board
T203
T202
T201
7.4. Phantom Power On/Off Setting for Microphone Input
The phantom power is set for ON or OFF by the unit's internal jumper switch JP201.
It is factory-preset for OFF.
Preamplifier board
OFF ON
T203
T202
T201
Jumper switch JP201
7.5. Changing MIC and PROGRAM Input Types
Both MIC and PROGRAM inputs can be changed from electronically-balanced to transformer-balanced types
in the procedures as follows.
7.5.1. MIC input
• Install an optional IT-450 Line Transformer in the specified location on the printed circuit board.
• Cut off the JP202 and JP203 jumper wires.
JP202
JP203
T203
T202
Preamplifier board
Line Transformer IT-450
12
7.5.2. Program input
• Install an optional IT-453A Line Transformer in the specified location on the printed circuit board.
• Cut off the JP205 and JP206 jumper wires.
Preamplifier board
T202
T201
JP206
JP205
Line Transformer
IT-453A
8. INSTALLATION
Keep the unit's all sides at least 10 cm away from
objects that may obstruct air flow to prevent the
unit's temperature from rising.
At least
10 cm
MIC
TEL
PROGRAM
AUX
MODULE
SIGNAL
PEAK
POWER
0
10
0
10
0
10
0
10
0
10
ON
OFF
INTEGRATED AMPLIFIER BG-1120
At least
10 cm
At least
10 cm
9. RACK MOUNTING
To mount the amplifier in a standard 19" equipment rack, use the optional MB-1000 Rack Mouting Kit.
Attach the MB-1000 to the amplifier using the supplied 4 screws. When using other screws, ensure that each
screw is shorter than 16 mm.
M4 x 16 Machine screw included in MB-1000
MB-1000
Amplifier
Amplifier
PF-511 Perforated Panel (1-unit size)
Amplifier
Note
Mount the Perforated Panel PF-511 above and below each amplifier
for ventilation inside the rack.
Amplifier
About the perforated panel, consult your TOA dealer.
Amplifier
13
10. CONTROL SETTINGS
Output levels are adjustable with individual volume controls. For music play or announcement, adjust the
corresponding volume control so that the signal indicator lights intermittently. Note that the sound quality is
downgraded when the peak indicator remains lit.
To prevent the accidental change of the settings of input volume controls, remove their knobs after setting
them to the desired position and attach the volume control covers instead.
L
E
T
C
I
M
0
0
Volume control cover (Accessory)
0
1
LIFIER BG-1120
TED AMP
GRA
TE
IN
Volume control knob
11. DIMENSIONAL DIAGRAM (Applicable to all models)
Unit: mm
120V 60Hz
MAX 500W
SENSE
UNIT
BREAKER
1.25A
OUTLET
BREAKER
4A
MUTE
MODULE
PUSH
RESET
PUSH
RESET
0
10
A
B
PAGE
BGM
PROGRAM
TEL
MIC
BASS
0
TREBLE
0
G
COM HOT
G
COM HOT
G
COM HOT NC
AUX
UNSWITCHED
–
+
–
+
OUTPUT 15W
OUTPUT 1W
MOH
MUTE
120V
40W
50Hz
PREAMP
OUT
POWER
IN
COM 4Ω
25V 70V
8Ω COM 600Ω COM
G
OUTPUT 1W
MOH
0
10
0
10
CLASS
2
WIRING
model BG-1015
264
280
266.5
MIC
TEL
PROGRAM
AUX
MODULE
SIGNAL
PEAK
POWER
0
10
0
10
0
10
0
10
0
10
ON
OFF
INTEGRATED AMPLIFIER BG-1015
14
12. BLOCK DIAGRAM
15
13. SPECIFICATIONS
BG-1015
15 W
BG-1030
120 V AC, 60 Hz
30 W
BG-1060
60 W
BG-1120
120 W
Model No.
Power Source
Rated Output
Power Consumption
Rated output
Based on UL/CSA standards
Frequency Response
Total Harmonic Distortion
Input
50 W
40 W
80 W
60 W
160 W
100 W
260 W
150 W
50 – 20,000 Hz
0.05% at 1 kHz, rated output
Mic:
Tel:
–60 dB*1, 600 Ω, electrically balanced, M3 screw terminal*2
–20 dB*1, 10 kΩ/600 Ω, balanced, M3 screw terminal*2
Program: –10 dB*1, 10 kΩ, electrically-balanced, M3 screw terminal*2
Aux:
–10 dB*1, 47 kΩ, unbalanced, 2P RCA pin jack (internal mixing)
Module: –20 dB*1, 10 kΩ, unbalanced, card edge connector
Power IN: 0 dB*1, 10 kΩ, unbalance, RCA pin jack
Mute:
M3 screw terminal*2
Main:
Sub:
MOH:
4 Ω, 25 and 70 V, balanced, M3 screw terminal*2
1 W/8 Ω, unbalanced, M3 screw terminal*2
0 dB*1, 600 Ω, balanced, M3 screw terminal*2
Output
Preamp OUT: 0 dB*1, 600 Ω, unbalance, RCA pin jack
Under 2 dB, no load to full load
Mic: 60 dB, Telephone: 75 dB, Program: 75 dB, Aux: 75 dB, Module: 75 dB
Output Regulation
S/N Ratio
(Band Pass: 20 – 20,000 Hz, Tone Controls: Centered)
Bass: 10 dB at 100 Hz, Treble: 10 dB at 10 kHz
Tone Controls
Controls affect only program input, aux input and module (BGM) input
Variable by heat sink temperature
Power LED, Signal LED, Peak LED
Cooling Fan Speed
Indicator
Self protection, with 1 AC breaker (outside)
Protection
Automatic electronic drive limiter
Other Feature
Output disconnected for approx. 3 seconds after the unit is turned on
Panel: ABS resin, black
Finish
Case: Steel plate, black, paint
264 (w) x 107.4 (h) x 280 (d) mm
Dimensions
Weight
(without input module)
4.5 kg
4.8 kg
5.6 kg
6.4 kg
*1 0 dB = 1 V
2 Distance between barriers on the above screw terminal: 6 mm
*
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
Volume control cover ........................................... 5
• Optional products
Line transformer: IT-450
Line transformer: IT-453A
133-12-819-0B
|